Refrigerant and Hydrogen Leak Detector- DXR-240

๐ŸŒ ย ย Hydrogen and Refrigerant Tracer Gas Leak Detector- DXR-240

The Handheld Leak Detector for Refrigeration and HVAC Systems Leak Detection

DXR-240 Refrigerant Leak Detector | Also Detects H2/N2 Tracer Gas | H2Leak
ALL-IN-ONE REFRIGERANT + TRACER GAS SOLUTION

One detector for the whole life of the system โ€” charged, or not charged yet.

The DXR-240 locates leaks in refrigeration and HVAC systems already running a refrigerant charge, and locates leaks in systems before they’re ever charged, using 5%H2/95%N2 non-combustible tracer gas. It’s the same tracer method as a helium leak detector, at roughly a fourth to a fifth of the tracer gas cost โ€” one tool covering every system condition you’ll run into.

H2Leak DXR-240 handheld refrigerant and hydrogen tracer gas leak detector
MADE IN FRANCE ยท OLED DISPLAY Full product information

Every other refrigerant detector does one job.

Refrigerant-only sniffers are only useful once a system is already charged. Helium tracer-gas detectors solve the pre-charge problem, but at a steep gas cost. The DXR-240 covers both, without either drawback.

Refrigerant-only detector Helium tracer detector DXR-240
Detects refrigerant gas (HFC / HFO / HC) Yes No Yes
Detects H2/N2 tracer gas No No (uses helium) Yes
Works on new, uncharged systems No Yes Yes
Works on evacuated systems mid-repair No Yes Yes
Reclaim required before repair Yes โ€” refrigerant reclaim No No
Tracer gas cost vs. H2/N2 โ€” 4โ€“5x higher Baseline
Units needed to cover both job types 2 2 1

Helium tracer-gas cost comparison based on typical per-fill pricing for 5%H2/95%N2 versus pure helium.

Built for every system condition, not just a full charge

Some of the most common leak-check jobs happen when there’s no refrigerant to detect in the first place.

CHARGED SYSTEMS

Refrigerant already in the line

Detect HFC, HFO, and HC refrigerants directly, down to 1 g/yr, on any system already running a charge.

NEW INSTALLATIONS

Nothing charged yet

Pressurize new piping with H2/N2 tracer gas and leak-check before a single ounce of refrigerant goes in.

EVACUATED SYSTEMS

Mid-repair, refrigerant removed

Once refrigerant is recovered for a repair, switch to tracer gas and keep testing without waiting on a recharge.

Tracer gas skips a step refrigerant can’t skip

Refrigerant is regulated and has to be recovered before you can safely open a system to repair a leak. The 5%H2/95%N2 mixture doesn’t carry that requirement.

Refrigerant gas workflow

01Recover refrigerant
02Charge / pressurize
03Scan for leak
04Repair
05Reclaim & recharge

H2/N2 tracer workflow

01Pressurize with H2/N2
02Scan for leak
03Repair
Non-toxic, non-flammable โ€” vent to atmosphere instead of reclaiming.

Why H2/N2 tracer gas is the smarter choice

It isn’t just a workaround for empty systems โ€” it’s also a straight replacement for helium leak detection, at a fraction of the tracer gas cost, with none of the reclaim burden refrigerant carries.

1ร—10โปโต cc/s
Minimum sensitivity for H2/N2 tracer mixture, roughly 1 g/yr refrigerant equivalent
1/4 โ€“ 1/5
The cost of helium tracer gas โ€” H2/N2 replaces helium leak detection at a fraction of the gas cost
$0
Recovery equipment or reclaim tank needed once the leak is found
Non-flammable
5% H2 / 95% N2 blend is safe to handle and vent, unlike pure hydrogen

Where technicians put it to work

Supermarket & grocery refrigeration racks
Cold storage & industrial refrigeration
VRF / VRV systems, chillers, rooftop units
Residential & commercial HVAC service
New piping system commissioning
EPA / GreenChill leak-rate compliance

Technical specifications

From the manufacturer datasheet. Full detail in the downloadable PDF.

Detected gasesHFO, HFC, HC, R290, R600, and 5%H2/95%N2 tracer gas
Sensitivity1 g/yr min. for HFC and HFO; 1 g/yr min. for R600 and R290; 1ร—10โปโต cc/s min. for H2/N2 tracer mixture (โ‰ˆ1 g/yr refrigerant equivalent)
Detection methodSuction-flow probe with fast response and degassing; 30 cm flexible probe with steel shape memory
Detection cellInterchangeable โ€” universal cell (refrigerant + H2/N2) or selective cell (H2/N2 only)
Warm-up / response time~60 seconds cell heating; ~1 second response
CalibrationAutomatic calibration and zeroing to ambient; 3 sensitivity presets (HI / MED / LO); selectable gas family (HFC, HFO, HC, H2/N2)
DisplayOLED graphic display; progressive graphic ramp with rising sound signal; battery level and ambient contamination indication
HousingShockproof plastic case, 0.350 kg
Power supplyBuilt-in rechargeable battery, ~8 hr autonomy; USB-C, full charge in ~12 hours
Operating conditions10โ€“40ยฐC, worksite and maintenance use. Non-explosion-proof โ€” never use in a hazardous or explosive atmosphere
IncludedTransport case, mains charger, user manual
MaintenanceWear parts (detection cell, flexible probe) are directly interchangeable; support and spares provided by manufacturer SAPRE
Made inFrance

One tool, more jobs you can take on

Tracer-gas capability opens up work a refrigerant-only sniffer has to turn down.

  • Take on commissioning jobs โ€” leak-check new installs before any refrigerant is ever charged.
  • Cut callback visits โ€” higher sensitivity catches leaks a soap test or basic sniffer misses.
  • Sell tightness testing as its own service โ€” a premium line most shops can’t offer.
  • Stand apart from single-mode competitors โ€” one detector for the whole job, not two tools in the truck.

Get the full DXR-240 spec sheet

Detected gases, sensitivity by refrigerant type, and field specifications in one PDF.

Download PDF
H2Leak โ€” hydrogen tracer gas leak detection for HVAC, refrigeration, and automotive service.
DXR-240 Product Page